Lab instrument-Incubator(New)
Mould Cultivation Cabinet
■Uses:
This equipment is widely used in environmental protection, epidemic prevention, workshop, chemical pharmaceutical, drug test, fishery and other areas of research experiment and production department. It is the specialized thermostatic equipment for water analysis, BOD test, and bacteria, moulds and microorganism cultivation and storage, as well as plant cultivation and seed-breeding test.
1. Stainless steel inner chamber; foursquare semicircle transition, convenient to clean,space between shelves is adjustable.
2. Micro-computer control system ensures precise and reliable temperature control; LCD enables multiple groups of data to be displayed at a time; ultraviolet germicidal lamp.
3. Independent humidification, sterilization and temperature limit system with function of over-temperature alarm and auto-power-cut-off.
4. Test hole of ¢52mm at left side of container.
5. Double airtight door structure.
6. Fluoride-free refrigeration.
■Characteristics of functional incubator:
1.Intelligent programmed temperature and humidity control system with program of 30 sections ensure timing,repeated or multistep running of temperature and humidity.
2.No freezing thanks to intelligent refrigeration and defrosting system.
3.Function of auto running, auto stopping and timing running, as well as parameter memorizing, power reset recovering and temperature display revising.
4.Watch timer and independent temperature safety device, which auto breaks off when over temperature limit.
5.Function of self-diagnosis, sensor failure alarm and over temperature protection.
Optional accessories:
a.Printer:RMB 1150 (desktop)
b.Supplementare oxygen,nitrogen interface:RMB 200
c.RS485 interface for communication software connection: RMB 800
.
■Main Parameters:
Model
|
Standard form
|
MJX-70BⅢ
|
MJX-150BⅢ
|
MJX-250BⅢ
|
Functional form
|
MJX-70BX
|
MJX-150BX
|
MJX-250BX
|
voltage
|
220V/50Hz
|
Tem.Range (℃)
|
With Humidification:10~65 Without Humidification:0~65℃
|
Tem.Resolution Ratio (℃)
|
0.1℃
|
Tem. volatility (℃)
|
High Temperature0.5℃
Low Temperature±1℃
|
Tem. uniformity (℃)
|
±1℃
|
Humidity range
|
60-90%RH
|
Humidity error
|
5-8%RH
|
Power (w)
|
300
|
500
|
800
|
Coolant
|
R134a
|
Amebient tem. (℃)
|
5-30℃
|
Inner Champer Size (mm)
|
420×350×500
|
500×400×750
|
500×500×950
|
Exterior Size (mm)
|
570×560×1200
|
640×620×1270
|
660×700×1470
|
Packing Size (mm)
|
730×720×1170
|
820×760×1430
|
880×825×1645
|
N.W. (Kg)
|
59.5
|
68.5
|
72
|
G.W.(Kg)
|
86
|
98
|
116
|
Timing
|
1-9999min
|